Piroshow has always been involved in the research of innovative and professional solutions to surprise their customers. Master modules are the max expression of this research: a unique product to manage an entire pyrotechnical show, synchronizing lights, audio, and fireworks!
Firing Module Master FullPower is all this and not only.
All firing functions remain unchanged, you will be able to execute the show in automatic, semi-automatic o manual mode. Also to create, modify and execute pyromusical shows, synchronize in their execution to external audio service, control and manage lights, flames (electro valves) and all the illumination and the stage effects.
Master FullPower adds the direct alimentation of 126 modules between SmartSlaves, FastSlaves creating a new ignition system that is versatile, light, and simple to use. SmartSlave and FastSlave are the new generations firing devices: without internal batteries, guarantee high performances and reliability even if they are small size, comfortable to transport, and simple to use. Combining two products with these characteristics allows having the excellence of the firing system.
UPDATE TO THE 2021 VERSION AVAILABLE (Cost € 600): Software update, introduction of new features such as: offset, FSK, speed, lock / unlock of an ID during the firing phase, etc. Hardware upgrade: audio and DMX input / output isolation, RF shielding and audio amplifier. Valid for all customers who own a Master FullPower in previous versions.

USB Input
Once you import the show from the simulator through a simple USB drive, the show can be modified directly in the Master and saved in the internal memory. Or can be created directly in the Master by using the simple interface of show creation. The internal memory of the Master allows to save hundreds of shows and, if you require, can be expanded. Once you have imported the show and removed the pen drive, the USB input can be used to connect a mouse or a keyboard to do the operation of modification or creation of the show or to assign a name more easily.

Audio Outputs
Besides the traditional shows, our Master allows, through the RCA output, to manage the pyromusical shows. The audio file must be imported from outside, via a USB port, once saved you can play it directly thanks to the integrated audio player.
TIME CODE SMPTE Inputs
The SMPTE input is the jewel in the crown of the Piroshow Masters, it allows the exploitation of the TIME CODE technology. The time code allows you to synchronize the list of ignitions programmed in the Master with external devices. In the case, for example, of pyromusical shows where the audio reproduction is entrusted to external services or highly complex shows with lighting effects entrusted to specialized companies, the TIME CODE simply ensures the perfect synchronization of the entire show.
The SMPTE input also allows to connect two or more Masters together to perform the same show: the system configured in this way is NO LIMITS! The number of Slaves and the number of ignitions that can be managed will depend only on the number of Full Masters connected.
In the new Master FullPower a new RCA type SMPTE input has been added because it is more common in use.
DC Input
The Direct Current input is the connector where you connect the battery charger to feed the Master FullPower. In case of emergency, to this input, you can connect an external power source, like a simple battery, able to provide the energy necessary for the success of the whole show.
Master FullPower has got a 12V battery that allows to feed up to 126 SmartSlave or FastSlave, this capacity is also supported by the new fast charger we will send you.
Master FullPower recharges in less than three hours!

Output connectors
Through these connectors, the Master FullPower manages and supplies the SmartSlave and Fast Slave modules. The connection can be made through a simple telephone pair cable or a common electric cable, sturdy and flexible, they allow to transmit the energy from the central source to all the connected modules.


Ethernet Connector
The Ethernet connector is fundamental in a new generation product that does not fear comparison. Through this connector it is possible, via an Ethernet cable, to connect to the network and download all the Firmware updates for your Master FullPower.
Piroshow Firing Module Master FullPower will always stay updated!
DMX Output
Through the DMX output, located on the back of the case, it is possible to manage the lights, the flames (solenoid valves), and any possible stage effects.
Bi-directional XLR ports
Master FullPower can manage a total of 126 Slave 30CH-100V or power a combination of 126 modules without an autonomous battery: SmartSlave and FastSlave. The XLR bidirectional ports allow you to connect the Master to the Slave 30CH-100V via RS 485 cable or via radio. The wireless technology allows the various modules to be connected, positioned even very far from each other, making the Master the ideal module to control, from a single position, traditional and pyromusical shows with very long firing front and with a very high number of firing positions
Modules without an autonomous battery, on the other hand, must be connected to the power supply connectors located on the front of the Master using a cable, whether it is a common electrical cable or a telephone pair cable.


At the same time, Master FullPower not only guarantees reliability at the highest levels but it has been designed to allow the pyrotechnician to recognize his own mistakes made during the design of the show, as well as during the positioning phase: Master FullPower in fact allows test all the Slave modules used in the performance of the show and the igniters connected to them. Its large screen allows you to view in a single view all the system used at the time and it’s simple white, red, blue, and green boxes to recognize and correct any mistakes made in advance.


From the Master FullPower is also possible to control the charge status of all the modules Slave 30CHs connected and put the system on stand-by once completed the test phase and then wake-up it to the execution with a simple click.
From the ID PROGRAM button, you can modify the identity of the SmartSlaves and SuperSlaves without using the ID programmer for each one.
The Firing Module Master FullPower gives the maximum flexibility in the planning and design of the shows:
Traditional shows:
- design directly in local, through the touch-screen control panel, by accessing the specific Create Show menu.
- import of the already definitive project (list), developed in the pyrotechnic simulator, through a USB pen-drive. The imported show will be saved in the internal memory and then executed. The show can also be modified: elimination of pyrotechnic passages or their replacement with different ones.
- modification of ignition times – addition of further ignitions – addition of lighting effects or stage effects directly in the Master through the Edit Show item.
Pyromusical shows:
- import of music tracks, in .mp3 or .wav format through the USB port and subsequent association to a firing list already present in the Master memory or design of the show list directly in the Master FullPower module through the control panel.
- importation of the music files and the firing list developed in the simulator through the USB input, synchronization through the control panel of the Master FullPower.
Shows with light effect or other stage effects:
- importation of the definitive project of the show, traditional or pyromusical, with the presence of stage effects and electro valves (flames) already planned in the simulator. Management of the lights effects or every other stage effect through DMX port.
- addition of stage effects to a show already memorized through the Edit Show menu or creation directly in the Master of a show with a simultaneous performance of stage effects through the Create Show menu.
Firing Mode:
Manual
Firstly, manual mode is to be used in absence of programming the show. Connecting the Slave to Master Full, by cable or RadioModem, the pyrotechnic will select, according to which is the progressive order of the show, the line, the slave, and the channel to be ignited pressing the FIRE button. Master Full predisposes for ignition always the channel after last executed, even in the case of jumping between different lines or different slave modules. A simple, but of great help, feature for the pyrotechnic because it speeds up the selection of the correct firing channel and prevents the possibility of running the wrong channel.
Automatic
Secondly, in automatic mode the project of the show programmed directly into the Master Full module or imported from the simulator via USB drive, is complete with all of its times including breaks and interruptions between a block of ignition and/or music tracks and another. It will be sufficient to press once the shoot button and follow the proper execution on the display.
Semiautomatic
Thirdly, the semiautomatic mode is selected when the show is scheduled in its list of ignition timing, but the pyrotechnic wants to reserve the opportunity to personally choose how and when to actually run the various blocks in which the show is ordered. In this mode, the time signature of the next shot provides an important aid to the previous one. The semiautomatic mode is realized by inserting from the “Create show” or ” Edit show” a pause (short pause) between a programmed block of ignitions and the other. The ignition of each subsequent block involves a new click on the FIRE button.
Via Time Code
After all, ignition via TIME CODE, an extraordinary innovation of Piroshow. It allows synchronizing the list planned on the Master with all external devices connected to it Its clock regulates all planned activities of all connected devices. The Time Code technology allows in this way to launch with a single click all instruments present in the run of the show. In the case ex. of pyrotechnic shows where audio is performed by external services or highly complex shows with light effects committed to specialized companies, Time Code ensures the perfect execution.



The Master Full carrying case and transport case is made of a special plastic polymer that guarantees impact resistance and extremely high-intensity use, according to what we might call “military” standards. It is also waterproof and equipped with a valve for checking internal pressure. It does not fear the use even in the most difficult weather conditions.

Characteristics Firing Module Master FullPower :
- 7″ touch screen display
- Standard modality: 2 lines, 126 Slaves, 3780 ignitions
- EXTENDED Modality: no limits to Slaves and ignitions
- Local planning
- Ignition lists and music files acquisition
- Reading of sequences in various formats
- Memorization of choreographies and entire shows
- Complete management Slave and channels test
- Alimentation connector for Smart Slaves and Fast Slaves
- Synchronization via TIME CODE
- Firing mode: MANUAL, SEMI-AUTOMATIC, AUTOMATIC
- SMPTE PORT: XLR 3 poles an RCA
- XLR stereo audio output (2 RCA)
- USB input
- DMX output – 512 channels
- Ethernet port
- Long-life rechargeable battery 12v-18Ah
- Upgradable firmware
- CE-ISO 9001 mark
- International warranty
- Fast battery charger
- Multilanguage menu: English, French, Spanish, Italian (other on request)
- Dimensions: 300x240x212mm
- Weight 9 KG